10225.305 37 

   ===========================================================================

                  Verbruiksgegevens Elektra en Gas                            
                                                                              
   Uitgelezen via:  P1 data-poort                                             
   Type meter:      Iskra SMR 5.0 AM550-TD2 / Landis+Gyr SMR 5.0 G4 G6        
   Programma:       Leesmeter.py 7.0
   Datafile:        Energie                                                   
   Datum:           03-01-2026
   Tijd:            01:55:22
   ___________________________________________________________________________

   Elektra
   =======
   Beginstand daltarief:                      11478.0 kWh
   Huidige stand daltarief:                   12135.4 kWh 

   Beginstand hoogtarief:                     10692.0 kWh
   Huidige stand hoogtarief:                  11321.8 kWh

   Verbruikte elektriciteit daltarief:          657.4 kWh - € 158.49
   Verbruikte elektriciteit hoogtarief:         629.8 kWh - € 151.92
   Totaal verbruikte elektriciteit:            1287.2 kWh - € 310.41

   Op dit moment afgenomen vermogen:            210.0  Wh - €   0.0501 per uur

   Gas
   ===
   Beginstand gas:                             9712.0  m3
   Huidige stand gas:                         10225.3  m3
   Verbruik gas:                                513    m3 - €  669.56

   Totale kosten
   =============
   Verbruikskosten elektra en gas:           €  979.97
   Maandelijkse kosten elektra:              €  237.80
   Maandelijkse kosten gas:                  €  141.47
   Vermindering energiebelasting:            € -268.00

   Totale kosten elektra en gas:             € 1091.24
   Betaald aan voorschotten:                 € 1184.75 

   Huidige stand voorschotten versus kosten: €   93.51 Tegoed

   Aantal storingen
   ================
   Stroom in elke fase:                          15
   Stroom langdurig in elke fase:                13


   ¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯
                   *** Detailregels Elektra- en Gasmeter ***

   Uitgelezen via: P1-datapoort
   Type meter:     Iskra SMR 5.0 AM550-TD2 / Landis+Gyr SMR 5.0 G4 G6
   Programma:      Leesregels.py 1.02

   Te doen:        Database vullen met code + omschrijving, deze joinen met LeesmeterDB
                   omschrijvingen op scherm tonen achter de codes met waarden

   Datum:          Sat,  3 Jan 2026  (Week 01)
   Tijd:           01:55:24 CET
   ____________________________________________________________________________________________________________________________________

   R#   Code                 Waarde                               Omschrijving
   ¯¯   ¯¯¯¯                 ¯¯¯¯¯¯                               ¯¯¯¯¯¯¯¯¯¯¯¯
    1 - /ISK5\\2M550T-1012 -                                    - Manufacturer code
    2 -                    -                                    - 
    3 - 1-3:0.2.8          - 50                                 - Version information for P1 output
    4 - 0-0:1.0.0          - 260103015524W                      - Date-time stamp of the P1 message
    5 - 0-0:96.1.1         - 4530303434303036393538353737323137 - Equipment identifier
    6 - 1-0:1.8.1          - 012135.410*kWh                     - Meter Reading electricity delivered to client (Tariff 1) in 0,001 kWh
    7 - 1-0:1.8.2          - 011321.839*kWh                     - Meter Reading electricity delivered to client (Tariff 2) in 0,001 kWh
    8 - 1-0:2.8.1          - 000000.003*kWh                     - Meter Reading electricity delivered by client (Tariff 1) in 0,001 kWh
    9 - 1-0:2.8.2          - 000000.007*kWh                     - Meter Reading electricity delivered by client (Tariff 2) in 0,001 kWh
   10 - 0-0:96.14.0        - 0001                               - Tariff indicator electricity
   11 - 1-0:1.7.0          - 00.210*kW                          - Actual electricity power delivered (+P) in 1 Watt resolution
   12 - 1-0:2.7.0          - 00.000*kW                          - Actual electricity power received (-P) in 1 Watt resolution
   13 - 0-0:96.7.21        - 00015                              - Number of power failures in any phase
   14 - 0-0:96.7.9         - 00013                              - Number of long power failures in any phase
   15 - 1-0:99.97.0        - 10 - 0-0:96.7.19                   - Power Failure Event Log (long power failures
   16 - 1-0:32.32.0        - 00011                              - Number of voltage sags in phase L1
   17 - 1-0:52.32.0        - 00013                              - Number of voltage sags in phase L2
   18 - 1-0:72.32.0        - 00011                              - Number of voltage sags in phase L3
   19 - 1-0:32.36.0        - 00001                              - Number of voltage swells in phase L1
   20 - 1-0:52.36.0        - 00001                              - Number of voltage swells in phase L2
   21 - 1-0:72.36.0        - 00001                              - Number of voltage swells in phase L3
   22 - 0-0:96.13.0        -                                    - Text message max 1024 characters
   23 - 1-0:32.7.0         - 231.0*V                            - Instantaneous voltage L1 in V resolution
   24 - 1-0:52.7.0         - 227.3*V                            - Instantaneous voltage L2 in V resolution
   25 - 1-0:72.7.0         - 227.8*V                            - Instantaneous voltage L3 in V resolution
   26 - 1-0:31.7.0         - 000*A                              - Instantaneous current L1 in A resolution
   27 - 1-0:51.7.0         - 000*A                              - Instantaneous current L2 in A resolution
   28 - 1-0:71.7.0         - 000*A                              - Instantaneous current L3 in A resolution
   29 - 1-0:21.7.0         - 00.000*kW                          - Instantaneous active power L1 (+P) in W resolution
   30 - 1-0:41.7.0         - 00.183*kW                          - Instantaneous active power L2 (+P) in W resolution
   31 - 1-0:61.7.0         - 00.026*kW                          - Instantaneous active power L3 (+P) in W resolution
   32 - 1-0:22.7.0         - 00.000*kW                          - Instantaneous active power L1 (-P) in W resolution
   33 - 1-0:42.7.0         - 00.000*kW                          - Instantaneous active power L2 (-P) in W resolution
   34 - 1-0:62.7.0         - 00.000*kW                          - Instantaneous active power L3 (-P) in W resolution
   35 - 0-1:24.1.0         - 003                                - Device-Type
   36 - 0-1:96.1.0         - 4730303332353635353439303030353137 - Equipment identifier (Thermal: Heat or Cold
   37 - 0-1:24.2.1         - 260103015506W - 10225.305*m        - Last 5-minute Meter reading Heat or Cold in 0,01 GJ and capture time
   ====================================================================================================================================