10225.305 37
===========================================================================
Verbruiksgegevens Elektra en Gas
Uitgelezen via: P1 data-poort
Type meter: Iskra SMR 5.0 AM550-TD2 / Landis+Gyr SMR 5.0 G4 G6
Programma: Leesmeter.py 7.0
Datafile: Energie
Datum: 03-01-2026
Tijd: 01:55:22
___________________________________________________________________________
Elektra
=======
Beginstand daltarief: 11478.0 kWh
Huidige stand daltarief: 12135.4 kWh
Beginstand hoogtarief: 10692.0 kWh
Huidige stand hoogtarief: 11321.8 kWh
Verbruikte elektriciteit daltarief: 657.4 kWh - € 158.49
Verbruikte elektriciteit hoogtarief: 629.8 kWh - € 151.92
Totaal verbruikte elektriciteit: 1287.2 kWh - € 310.41
Op dit moment afgenomen vermogen: 210.0 Wh - € 0.0501 per uur
Gas
===
Beginstand gas: 9712.0 m3
Huidige stand gas: 10225.3 m3
Verbruik gas: 513 m3 - € 669.56
Totale kosten
=============
Verbruikskosten elektra en gas: € 979.97
Maandelijkse kosten elektra: € 237.80
Maandelijkse kosten gas: € 141.47
Vermindering energiebelasting: € -268.00
Totale kosten elektra en gas: € 1091.24
Betaald aan voorschotten: € 1184.75
Huidige stand voorschotten versus kosten: € 93.51 Tegoed
Aantal storingen
================
Stroom in elke fase: 15
Stroom langdurig in elke fase: 13
¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯
*** Detailregels Elektra- en Gasmeter ***
Uitgelezen via: P1-datapoort
Type meter: Iskra SMR 5.0 AM550-TD2 / Landis+Gyr SMR 5.0 G4 G6
Programma: Leesregels.py 1.02
Te doen: Database vullen met code + omschrijving, deze joinen met LeesmeterDB
omschrijvingen op scherm tonen achter de codes met waarden
Datum: Sat, 3 Jan 2026 (Week 01)
Tijd: 01:55:24 CET
____________________________________________________________________________________________________________________________________
R# Code Waarde Omschrijving
¯¯ ¯¯¯¯ ¯¯¯¯¯¯ ¯¯¯¯¯¯¯¯¯¯¯¯
1 - /ISK5\\2M550T-1012 - - Manufacturer code
2 - - -
3 - 1-3:0.2.8 - 50 - Version information for P1 output
4 - 0-0:1.0.0 - 260103015524W - Date-time stamp of the P1 message
5 - 0-0:96.1.1 - 4530303434303036393538353737323137 - Equipment identifier
6 - 1-0:1.8.1 - 012135.410*kWh - Meter Reading electricity delivered to client (Tariff 1) in 0,001 kWh
7 - 1-0:1.8.2 - 011321.839*kWh - Meter Reading electricity delivered to client (Tariff 2) in 0,001 kWh
8 - 1-0:2.8.1 - 000000.003*kWh - Meter Reading electricity delivered by client (Tariff 1) in 0,001 kWh
9 - 1-0:2.8.2 - 000000.007*kWh - Meter Reading electricity delivered by client (Tariff 2) in 0,001 kWh
10 - 0-0:96.14.0 - 0001 - Tariff indicator electricity
11 - 1-0:1.7.0 - 00.210*kW - Actual electricity power delivered (+P) in 1 Watt resolution
12 - 1-0:2.7.0 - 00.000*kW - Actual electricity power received (-P) in 1 Watt resolution
13 - 0-0:96.7.21 - 00015 - Number of power failures in any phase
14 - 0-0:96.7.9 - 00013 - Number of long power failures in any phase
15 - 1-0:99.97.0 - 10 - 0-0:96.7.19 - Power Failure Event Log (long power failures
16 - 1-0:32.32.0 - 00011 - Number of voltage sags in phase L1
17 - 1-0:52.32.0 - 00013 - Number of voltage sags in phase L2
18 - 1-0:72.32.0 - 00011 - Number of voltage sags in phase L3
19 - 1-0:32.36.0 - 00001 - Number of voltage swells in phase L1
20 - 1-0:52.36.0 - 00001 - Number of voltage swells in phase L2
21 - 1-0:72.36.0 - 00001 - Number of voltage swells in phase L3
22 - 0-0:96.13.0 - - Text message max 1024 characters
23 - 1-0:32.7.0 - 231.0*V - Instantaneous voltage L1 in V resolution
24 - 1-0:52.7.0 - 227.3*V - Instantaneous voltage L2 in V resolution
25 - 1-0:72.7.0 - 227.8*V - Instantaneous voltage L3 in V resolution
26 - 1-0:31.7.0 - 000*A - Instantaneous current L1 in A resolution
27 - 1-0:51.7.0 - 000*A - Instantaneous current L2 in A resolution
28 - 1-0:71.7.0 - 000*A - Instantaneous current L3 in A resolution
29 - 1-0:21.7.0 - 00.000*kW - Instantaneous active power L1 (+P) in W resolution
30 - 1-0:41.7.0 - 00.183*kW - Instantaneous active power L2 (+P) in W resolution
31 - 1-0:61.7.0 - 00.026*kW - Instantaneous active power L3 (+P) in W resolution
32 - 1-0:22.7.0 - 00.000*kW - Instantaneous active power L1 (-P) in W resolution
33 - 1-0:42.7.0 - 00.000*kW - Instantaneous active power L2 (-P) in W resolution
34 - 1-0:62.7.0 - 00.000*kW - Instantaneous active power L3 (-P) in W resolution
35 - 0-1:24.1.0 - 003 - Device-Type
36 - 0-1:96.1.0 - 4730303332353635353439303030353137 - Equipment identifier (Thermal: Heat or Cold
37 - 0-1:24.2.1 - 260103015506W - 10225.305*m - Last 5-minute Meter reading Heat or Cold in 0,01 GJ and capture time
====================================================================================================================================